Altherma ERHQ016BAV3 Spécifications Page 55

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 60
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 54
55
Solar connection EKSOLHWAV1
Dimensions Unit
HeightxWidthxDepth
mm
Weight Unit kg
Operation range Ambient
temperature
Min.~Max. °C
Sound pressure
level
Nom. dBA
Thermal
performance
Zero loss collector eciency η0 %
Power supply Phase/Frequency/Voltage Hz/V
Power supply intake Indoor unit
Accessory EKSR3PA
Mounting On wall
Dimensions Unit
HeightxWidthxDepth
mm
Thermal
performance
Zero loss collector eciency η0 %
Control Type Digital temperature dierence controller with plain text display
Power consumption W
Sensor Solar panel temperature sensor Pt1000
Storage tank sensor PTC
Return ow sensor PTC
Feed temperature and ow sensor Voltage signal (3.5V DC)
Power supply Frequency;Voltage Hz;V
770x305x270
8
1~35
27
-
1~/50/220-240
332x230x145
-
2
50;230
Solar collector EKSV26P EKSH26P
Dimensions Unit
HeightxWidthxDepth
mm
Weight Unit kg
Volume l
Surface Outer
Aperture
Absorber
Coating Micro-therm (absorption max.96%, Emission ca. 5% +/-2%)
Absorber Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate
Glazing Single pane safety glass, transmission +/- 92%
Allowed roof angle Min.~Max. °
Operating
pressure
Max. bar
Stand still
temperature
Max. °C
Thermal
performance
Zero loss collector eciency η0 %
Heat loss coecient a1 W/m².K
Temperature dependence of the
heat loss coecient a2
W/m².K²
Thermal capacity kJ/K
Incident angle
modier
AM at 50°
Installed position Vertical Horizontal
2,000x1,300x85 1,300x2,000x85
43
1.7 2.1
2.601
2.364
2.354
15~80
6
200
78.7
4,270
0.0070
6.5
0.94
Indoor units FWXV20AVEB FWXV15AVEB
Heating capacity Total capacity Nom. kW
Cooling capacity Total capacity Nom. kW
Sensible
capacity
Nom. kW
Power input Heating Nom. kW
Cooling Nom. kW
Dimensions Unit Height/Width/
Depth
mm
Weight Unit kg
Piping
connections
Drain/OD/Inlet/Outlet mm/inch
Sound pressure
level
Heating Nom. dBA
Cooling Nom. dBA
Power supply Phase/Frequency/Voltage Hz/V
(1) Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. | (2) Heating: room temperature 20°CDB and entering
water temperature 45°C, water temperature drop 5K.
2.0 1.5
1.7 1.2
1.4 0.98
0.015 0.013
0.015 0.013
600/700/210
15
18/G 1/2/G 1/2
29 19
29 19
1~/50/60/220-240/220
SOLAR CONNECTION
SOLAR COLLECTOR
HEAT PUMP CONVECTOR
DAIKIN ALTHERMA LOW TEMPERATURE
(1)Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K.(2)Heating: room temperature 20°CDB and entering water temperature 45°C, water temperature drop 5K.
Vue de la page 54